Li6Y6Y

Изображение кабеля Li6Y6Y Faber Кabel

Teflon insulated cable Li6Y6Y

Использование

FEP-insulated cables are preferably used as insulation cables in switch cabinet construction with increased requirements on the thermal and chemical resistance, e.g. in ovens, kitchen appliances and measuring devices. They are flame-resistant and also resistant to most chemicals and solvents.

Конструкция

Customs Tariff Number (code number) 85444995900000000
Conductor material tinned copper
Conductor construction Class 5 = flexible
Insulation FEP
Sheathing material FEP
Colour of outer sheath black
Flame-retardant VDE 0482-332-1-2/IEC 60332-1-2
UV-resistant yes
Oil-resistant yes
Chemical-resistant ja
Radiation resistance 1x 10exp6 cJ/kg
Permitted outer cable temperature, fixed, °C -100 - +205 °C
Bending radius, fixed installation 4 x Ø
Bending radius, moving application 15 x Ø
Insulation resistance 2000 MOhmxkm
Nominal voltage U 600 V
Colour of outer sheath black
metal base Cu 150 EUR/100 kg
Unit of measurement metre

Стандарты

FEP-insulated cables are preferably used as insulation cables in switch cabinet construction with increased requirements on the thermal and chemical resistance, e.g. in ovens, kitchen appliances and measuring devices. They are flame-resistant and also resistant to most chemicals and solvents.
Артикул Типоразмер кабеля
032145 Li6Y6Y-JZ 5X2.5 600 V BK
033854 Li6Y6Y-JZ 4X1.5 600 V BK
034824 Li6Y6Y-JZ 7X0.75 600 V BK
034905 Li6Y6Y-JZ 4X0.75 600 V BK
Логотип компании FABER Kabel